Products

Networking Products

NetIron CES 2000

NetIron CES 2000 Series Overview

NetIron
CES
2024C
NetIron
CES
2024F
NetIron
CES
2048C
NetIron
CES
2048F
NetIron
CES
2048CX
NetIron
CES
2048FX
Port density 24
10/100/1000 RJ45 ports with optional slot for 2x10 GbE XFP uplinks
24
100/1000 Hybrid Fiber SFP ports with optional slot for 2x10 GbE XFP uplinks
48
10/100/1000 RJ45 ports
48
100/1000 SFP ports
48
10/100/1000 RJ45 ports with 2x10 GbE XFP uplinks
48
100/1000 Hybrid Fiber SFP ports with 2x10 GbE XFP uplinks
10 G uplinks Yes
(optional slot for 2×10 GbE XFP uplinks)(optional slot for 2×10 GbE XFP uplinks)
Yes
(optional slot for 2×10 GbE XFP uplinks)
No No Yes
(optional slot for 2×10 GbE XFP uplinks)(built in)
Yes
(optional slot for 2×10 GbE XFP uplinks)(built in)
Combination ports Yes
(4 100/1000 SFP ports)
Yes
(4 10/100/1000 RJ45 ports)
Yes
(4 100/1000 SFP ports)
No No No
Forwarding performance 48 Gbps
88 Gbps (with 2x10 GbE module installed)
48 Gbps
88 Gbps (with 2x10 GbE module installed)
96 Gbps 96 Gbps 136 Gbps 136 Gbps
Packet forwarding performance 36 Mpps
65 Mpps (with 2x10 GbE module installed)
36 Mpps
65 Mpps (with 2x10 GbE module installed)
71 Mpps 71 Mpps 101 Mpps 101 Mpps
Buffering 64 MB
128 MB (with 2x10 GbE uplinks)
64 MB
128 MB (with 2x10 GbE uplinks)
128 MB 128 MB 192 MB 192 MB
Power supply options Internal AC or DC Internal AC or DC Internal AC or DC Internal AC or DC Internal AC or DC Internal AC or DC
Power supply redundancy 1+1 1+1 1+1 1+1 1+1 1+1
Fan redundancy M+N M+N M+N M+N M+N M+N
Airflow Front to back Front to back Front to back Front to back Front to back Front to back


NetIron CES 2000 Series Power Specifications



Configuration
Maximum AC Power Consumption (Watts) (100 to 240V AC)
Maximum DC Power Consumption (Watts)

Maximum Thermal Output (BTU/hour)
NetIron CES 2024C 120 120 410
NetIron CES 2024C with 2x10 G uplink 170 170 580
NetIron CES 2024F 145 145 495
NetIron CES 2024F with 2x10 G uplink 195 195 666
NetIron CES 2048C 205 205 700
NetIron CES 2048CX 255 255 870
NetIron CES 2048F 245 245 836
NetIron CES 2048FX 295 295 1007
Environmental
Operating Temperature 0°C to 40°C (32°F to 104°F)
Relative Humidity 5% to 90% at 40°C (104°F), non-condensing
Operating Altitude 10,000 ft (3048 m)
Storage Temperature –25°C to 70°C (–13°F to 158°F)
Storage Humidity 95% maximum relative humidity, non-condensing
Storage Altitude 15,000 ft (4500 m) maximum
Electromagnetic emission
ICES-003 Electromagnetic Emission
FCC Class A
EN 55022/CISPR-22 Class A/VCCI Class A
AS/NZS 55022
EN 61000-3-2 Power Line Harmonics
EN 61000-3-3 Voltage Fluctuation and Flicker
EN 61000-6-3 Emission Standard (Supersedes: EN 50081-1)
Immunity
EN 61000-6-1 Generic Immunity and Susceptibility. This supersedes EN 50082-1.
EN 55024 Immunity Characteristics. This supersedes:

EN 61000-4-2 ESD
EN 61000-4-3 Radiated, radio frequency, electromagnetic field
EN 61000-4-4 Electrical fast transient
EN 61000-4-5 Surge
EN 61000-4-6 Conducted disturbances induced by radiofrequency fields
EN 61000-4-8 Power frequency magnetic field
EN 61000-4-11 Voltage dips and sags
Safety agency approvals
CAN/CSA-C22.2 No. 60950-1-3
UL 60950-1
IEC 60950-1
EN 60950-1 Safety of Information Technology Equipment
EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification, Requirements and User’s Guide
EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems
IEEE compliance
IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX, 100Base-FX, 100Base-LX
IEEE 802.3z 1000Base-SX/LX
IEEE 802.3ab 1000Base-T
802.3 CSMA/CD AcCERs Method and Physical Layer Specifications
802.3ae 10 Gigabit Ethernet
802.3x Flow Control
802.3ad Link Aggregation
802.1Q Virtual Bridged LANs
802.1D MAC Bridges
802.1w Rapid STP
802.1s Multiple Spanning Trees
802.1x Port-based Network Access Control
802.1ad Provider Bridges
802.1ah Provider Backbone Bridges
802.1ag Connectivity Fault Management (CFM)
802.1ab Link Layer Discovery Protocol
802.1ah Provider Backbone Bridging
Telco NEBS/ETSI
Telcordia GR-63-CORE NEBS Requirements: Physical Protection
Telcordia GR-1089-CORE EMC and Electrical Safety
Telcordia SR-3580 Level 3
ETSI ETS 300-019 Physical Protection:

Part 1-1, Class 1.1, Partly Temperature Controlled Storage
Locations
Part 1-2, Class 2.3, Public Transportation
Part 1-3, Class 3.1, Temperature Controlled Locations (Operational)
ETSI ETS 300-386 EMI/EMC