Products

Data Storage Products

Vault X-Series

 

Starter

1 System

2 System

4 System

6 System

8 System

 

System

 

Cluster

Cluster

Cluster

Cluster

N-way Active

2

2

4

8

12

16

Controllers

 

 

 

 

 

 

SSD enclosures

1

1

2

4

6

8

(25 SSDs each)

 

 

 

 

 

 

Number of SSDs

13

25

50

100

150

200

 

expandable

 

 

 

 

 

 

to 25

 

 

 

 

 

Battery Backup Units

2

2

2

4

6

8

 

 

 

 

 

 

 

Infiniband Switches

0

0

2

2

2

8

 

 

 

 

 

 

 

AC Input Voltage

220V AC

220V AC

220V AC

220V AC

220V AC

220V AC

 

 

 

 

 

 

 

DC Input Voltage

-40V DC to

-40V DC to

-40V DC to

-40V DC to

-40V DC to

-40V DC to

 

-72V DC

-72V DC

-72V DC

-72V DC

-72V DC

-72V DC

Power Consump.

750W

816W

1,749W

3,367W

4,985W

6,603W

(typical)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rack Space

6U

6U

13U

23U

33U

43U

 

 

 

 

 

 

 

Weight (incl. rack)

252 / 557

255 / 563

349 / 769

502 / 1,106

654 / 1,443

827 / 1,824

(kg/lbs.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight (w/o rack)

94 / 208

99 / 213

190 / 419

344 / 756

497 / 1,093

618/1,362

(kg/lbs.)

 

 

 

 

 

 

Cooling Req.

2,576

2,576

5,500

10,612

15,724

20,836

(BTU/hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance (100%

 

 

 

 

 

 

rand. IOs, no cache,

Starter

1 System

2 System

4 System

6 System

8 System

on precond. &

prefilled arrays)

System

 

Cluster

Cluster

Cluster

Cluster

 

 

 

 

 

 

 

IOPS 70% read,

150,000

150,000

300,000

600,000

900,000

1,200,000

30% write, 8K blks

 

 

 

 

 

 

Average Latency

0.5

0.5

0.5

0.5

0.5

0.5

(ms)

 

 

 

 

 

 

Max. Bandwidth

3

3

6

12

18

24

(GB/s)

 

 

 

 

 

 

Host Connectivity

 

 

 

 

 

 

(Based on # of

Starter

1 System

2 System

4 System

6 System

8 System

systems in array)

System

 

Cluster

Cluster

Cluster

Cluster

 

 

 

 

 

 

 

FC Ports

4

4

8

16

24

32

(8Gbps)

 

 

 

 

 

 

 

 

 

 

 

 

 

iSCSI Ports

4

4

8

16

24

32

(10Gbps)

 

 

 

 

 

 

 

Starter

1 System

2 System

4 System

6 System

8 System

Management

System

 

Cluster

Cluster

Cluster

Cluster

Ethernet Ports

2

2

4

8

12

16

(1Gbps)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Management IP

1 (XMS)

1 (XMS)

1 (XMS)

1 (XMS)

1 (XMS)

1 (XMS)

 

2 (Array)

2 (Array)

4 (Array)

8 (Array)

12 (Array)

16 (Array)

 

 

 

 

 

 

 

XMS Management

A single XMS manages multiple Vault X-Series arrays (physical server or VM)

System Capacity

1 System

2 System

4 System

6 System

8 System

(40TB System)

 

Cluster

Cluster

Cluster

Cluster

Raw Capacity (TB/TiB)

40 / 36.4

80 / 72.8

160 / 145.5

240 / 218.3

320 / 291.0

 

 

 

 

 

 

Usable Capacity*

33.6 / 30.6

67.3 / 61.1

134.4 / 122.2

201.5 / 183.3

268.7 / 244.4

 

 

 

 

 

 

Effective Capacity*

201.6 / 183.3

403.1 / 366.6

806.2 / 733.2

1,209 / 1,100

1,612 / 1,466

System Capacity

1 System

2 System

4 System

6 System

8 System

(20TB System)

 

Cluster

Cluster

Cluster

Cluster

 

Raw Capacity (TB/TiB)

20 / 18.2

40 / 36.4

80 / 72.8

120 / 109.1

160 / 145.5

 

 

 

 

 

 

 

Usable Capacity*

16.7 / 15.2

33.3 / 30.3

66.7 / 60.6

100 / 91

133.3 / 121.3

 

 

 

 

 

 

 

 

Effective Capacity*

100.2 / 91.2

200.4 / 182.4

400.8 / 363.6

600 / 546

800 / 728

 

 

 

 

 

 

 

 

System Capacity

1 System

2 System

4 System

6 System

8 System

(10TB System)

 

Cluster

Cluster

Cluster

Cluster

Raw Capacity (TB/TiB)

10 / 9.1

20 / 18.2

40 / 36.4

N/A

N/A

 

 

 

 

 

 

Usable Capacity*

8.33 / 7.6

16.7 / 15.2

33.3 / 30.3

N/A

N/A

 

 

 

 

 

 

Effective Capacity*

50 / 45.5

100 / 91

200 / 182

N/A

N/A

 

 

 

 

 

 

Starter System

 

 

 

 

 

Capacity (5.2TB)

 

 

 

 

 

Raw Capacity (TB/TiB)

5.2 / 4.7

 

 

 

 

 

 

 

 

 

 

Usable Capacity*

3.6 / 3.3

 

 

 

 

 

 

 

 

 

 

Effective Capacity*

21.5 / 19.5

 

 

 

 

 

 

 

 

 

 

Starter systems may be expanded to 10TB by adding SSDs. They may then be scaled-out to two and four Vault X-Series clusters.

*Usable capacity is the amount of unique, non-compressible data that can be written into the array.

*Effective capacity includes the benefits of thin provisioning, inline global deduplication, inline compression, and space-efficient copies. Datasheet numbers are a representative example at 6:1 and will vary based on each customer’s specific application environment and use of the array.





COMPONENT SPECIFICATIONS

Array Controller

AC Input Voltage

90-264V, 47-63Hz single phase

 

 

DC Input Voltage

-40V DC to -72V DC

 

 

Rack Space

1U

 

 

Dimensions

43.2mm x 438mm x 709mm

(height x width x depth)

(1.7”x 17.25” x 27.9”)

Weight

18.1kg (40 lbs.)

 

 

Power Consumption

309W

(typical)

 





Disk Array Enclosure (DAE)

AC Input Voltage

100-240V, 50-60Hz single

 

phase

DC Input Voltage

-40V DC to -72V DC

 

 

Rack Space

2U

 

 

Dimensions

88.9mm x 438mm x 330mm

(height x width x depth)

(3.5”x 17.25” x 13”)

 

 

Weight

20.4kg (45 lbs.)

 

 

Power Consumption

185W

(typical)

 





Environmental

Operating Temperature

-5C to 55C

 

 

Relative Humidity

5% to 90%

 

 

Altitude

up to 3960m (13,000ft)

 

 





Battery Backup Unit

AC Input Voltage

160-294V, 50-60Hz

 

 

DC Input Voltage

-40V DC to -72V DC

 

 

Rack Space

1U

 

 

Dimensions

43.2mm x 438mm x 709mm

(height x width x depth)

(1.7”x 17.25” x 27.9”)

Weight

20kg (44 lbs.)

 

 


Infiniband Switch

(Two Included with Multi System Arrays)

Ports

18 per switch (36 total)

 

 

AC Input Voltage

100-240V, 50-60Hz

 

 

DC Input Voltage

-40V DC to -72V DC

 

 

Rack Space

2U (two 1U switches) +

 

1U for cabling

 

 

Dimensions

43.7mm x 428mm x 627mm

(height x width x depth)

(1.72”x 16.84”x 24.7

Weight

18.6kg (41.0 lbs.)

 

 

Power Consumption

65W

(typical)

 







For more information, please contact your Vector Data account manager.

All brands or products are trademarks or registered trademarks of their respective holders and should be treated as such.